Power System Analysis and Load Flow MCQs 2026
69 questions with detailed answers · 44 from past papers · 7 quiz batches available
Choose a Quiz Batch. Each batch has 10 questions from this topic, in order. Take them one by one to work through all 69 MCQs. Login to save your scores and see your best per batch.
Read each question, think about the answer, then click Show Answer to reveal the correct option and explanation. Load 10 at a time so it stays manageable — perfect for one-topic study sessions on the bus or during a break.
- Q1medium
Gauss-Seidel update for PQ bus uses
💡 Explanation:Bus equations relate specified P,Q to surrounding voltages.
- Q2Past Paper · PPSC/FPSC/NTSeasy
Admittance matrix Y-bus of a power network relates
💡 Explanation:Y-bus is the fundamental linear network model for load-flow and fault studies.
- Q3Past Paper · PPSC/FPSC/NTSmedium
Diagonal element Yii of Y-bus equals
💡 Explanation:Self-admittance includes all branches incident on node i.
- Q4Past Paper · PPSC/FPSC/NTSmedium
Off-diagonal element Yij of Y-bus for i ≠ j with direct branch between nodes is
💡 Explanation:Mutual terms are −yij for single series branch between nodes.
- Q5Past Paper · PPSC/FPSC/NTSeasy
Y-bus of a large transmission network is typically
💡 Explanation:Sparse structure enables efficient solution algorithms.
- Q6Past Paper · PPSC/FPSC/NTShard
Including transformer off-nominal tap in Y-bus requires
💡 Explanation:Tap ratio a affects both magnitude and angle of transformer model.
- Q7Past Paper · PPSC/FPSC/NTSmedium
Line charging susceptance in π-model contributes to Y-bus as
💡 Explanation:Half-line charging is placed at each end in nominal π representation.
- Q8Past Paper · PPSC/FPSC/NTSeasy
Grounded shunt capacitor bank at a bus adds to Y-bus
💡 Explanation:Capacitor increases jB at the connected node.
- Q9hard
Mutual coupling between transmission lines on same tower appears in Y-bus as
💡 Explanation:Line coupling links electrically distinct node pairs.
- Q10Past Paper · PPSC/FPSC/NTSmedium
Assembly of Y-bus from branch data is called
💡 Explanation:Each branch stamps its 2×2 (or larger) contribution into Y.
- Q11Past Paper · PPSC/FPSC/NTSeasy
Per unit system simplifies Y-bus construction because
💡 Explanation:Consistent MVA and kV bases normalize network elements.
- Q12Past Paper · PPSC/FPSC/NTSmedium
Singular Y-bus (no reference) occurs if
💡 Explanation:A reference node fixes one voltage magnitude and angle.
- Q13Past Paper · PPSC/FPSC/NTSmedium
Z-bus is related to Y-bus by
💡 Explanation:Driving-point and transfer impedances come from Z-bus.
- Q14Past Paper · PPSC/FPSC/NTSmedium
Modified Y-bus for fault studies may insert
💡 Explanation:Fault connection adds large admittance or alters network at fault point.
- Q15hard
Three-phase Y-bus can be built from
💡 Explanation:Unbalanced systems may require coupled 3n×3n Y or sequence methods.
- Q16Past Paper · PPSC/FPSC/NTSeasy
Equivalent π parameters of a line branch for Y-bus come from
💡 Explanation:π model yields series y and shunt jB/2 at each end.
- Q17Past Paper · PPSC/FPSC/NTSmedium
Y-bus symmetry for passive network without phase shifters means
💡 Explanation:Reciprocal network admittance matrix is symmetric.
- Q18hard
Phase-shifting transformer introduces in Y-bus
💡 Explanation:PSD flow controllers modify power flow via phase angle injection.
- Q19Past Paper · PPSC/FPSC/NTSeasy
Load-flow study computes
💡 Explanation:Steady-state power flow balances P and Q at each bus.
- Q20medium
Weakly meshed distribution feeders may converge with GS when
💡 Explanation:GS works for smaller or well-conditioned networks.
- Q21Past Paper · PPSC/FPSC/NTSeasy
PV bus in load flow specifies
💡 Explanation:PV (generator) bus controls P and V; Q varies to maintain V.
- Q22Past Paper · PPSC/FPSC/NTSeasy
Slack (swing) bus in load flow specifies
💡 Explanation:Slack absorbs mismatch in total P and Q generation vs load.
- Q23Past Paper · PPSC/FPSC/NTSeasy
PQ bus in load flow specifies
💡 Explanation:Load buses have specified P and Q; V is unknown.
- Q24Past Paper · PPSC/FPSC/NTSmedium
Gauss-Seidel method solves load flow by
💡 Explanation:GS uses most recent voltages when updating each bus sequentially.
- Q25medium
Acceleration factor in Gauss-Seidel can
💡 Explanation:Over-relaxation (α > 1) may improve convergence rate.
- Q26Past Paper · PPSC/FPSC/NTSmedium
Convergence of Gauss-Seidel is generally
💡 Explanation:NR quadratic convergence beats GS linear rate for tight tolerance.
- Q27Past Paper · PPSC/FPSC/NTSeasy
Initial voltage guess for GS load flow often sets
💡 Explanation:Flat start is common unless better estimate available.
- Q28Past Paper · PPSC/FPSC/NTShard
Reactive power limit violation at PV bus during GS iteration requires
💡 Explanation:When Q hits limit, voltage can no longer be held; bus becomes PQ.
- Q29easy
Number of iterations in GS depends on
💡 Explanation:Tighter ε and difficult cases need more passes.
- Q30Past Paper · PPSC/FPSC/NTSmedium
After GS converges, line flows are computed from
💡 Explanation:Sij = Vi(Vi−Vj)Yij* etc. from solved voltages.
- Q31easy
Gauss-Seidel is attractive for teaching because
💡 Explanation:Educational simplicity; less used in large commercial tools than NR.
- Q32Past Paper · PPSC/FPSC/NTSmedium
Mismatch at a bus in load flow is
💡 Explanation:ΔP and ΔQ drive iterative correction toward convergence.
- Q33Past Paper · PPSC/FPSC/NTSeasy
Stopping criterion for GS typically checks
💡 Explanation:max|ΔP|,|ΔQ| < ε across buses ends iteration.
- Q34hard
Distributed slack shares
💡 Explanation:Multiple slack generators share imbalance per defined weights.
- Q35Past Paper · PPSC/FPSC/NTSmedium
Newton-Raphson load flow linearizes
💡 Explanation:NR solves ΔF = −J·Δx iteratively.
- Q36Past Paper · PPSC/FPSC/NTShard
Jacobian matrix in NR contains partial derivatives of
💡 Explanation:J includes ∂P/∂θ, ∂P/∂V, ∂Q/∂θ, ∂Q/∂V blocks.
- Q37hard
Quadratic convergence of Newton-Raphson near solution means
💡 Explanation:Good initial guess yields very fast NR convergence.
- Q38Past Paper · PPSC/FPSC/NTSmedium
Fast decoupled load flow approximates Jacobian by
💡 Explanation:B′ and B″ matrices replace full Jacobian for speed.
- Q39Past Paper · PPSC/FPSC/NTSmedium
PV bus treatment in NR includes
💡 Explanation:PV buses add P-specified equation and V magnitude constraint.
- Q40hard
Ill-conditioned cases for NR include
💡 Explanation:Near singularity of J slows or stalls convergence.
- Q41hard
Rectangular coordinates (e,f) alternative in NR uses
💡 Explanation:Rectangular form avoids trig in some formulations.
- Q42hard
Optimal multiplier in NR can
💡 Explanation:Line search/optimal multiplier helps difficult cases.
- Q43hard
After NR solution, LMP or marginal loss calculations may use
💡 Explanation:Post-convergence analytics use power flow Jacobian inverse sensitivities.
- Q44hard
Continued power flow uses NR with parameterization to trace
💡 Explanation:CPF finds maximum loadability margin.
- Q45Past Paper · PPSC/FPSC/NTSeasy
NR is preferred in commercial EMS for
💡 Explanation:Industry standard for bulk power flow.
- Q46hard
Symmetric Jacobian structure is not generally symmetric because
💡 Explanation:Full NR Jacobian is nonsymmetric though Y may be symmetric.
- Q47Past Paper · PPSC/FPSC/NTSmedium
Updating voltage in polar NR computes
💡 Explanation:Corrections added to current θ and V each iteration.
- Q48medium
Flat start for NR on stiff EHV system may require
💡 Explanation:Difficult cases need engineering initial guesses or homotopy.
- Q49hard
Transformer regulating tap change during NR may use
💡 Explanation:Tap is discrete; outer control adjusts tap after flow solution.
- Q50medium
Loss allocation after NR can use
💡 Explanation:Loss formulas distribute line losses to generators/loads.
- Q51Past Paper · PPSC/FPSC/NTSeasy
Symmetrical three-phase fault has
💡 Explanation:Balanced fault simplifies to positive sequence network only.
- Q52Past Paper · PPSC/FPSC/NTSmedium
Line-to-line fault (LL) contains
💡 Explanation:LL is unbalanced but lacks zero sequence if system ungrounded.
- Q53Past Paper · PPSC/FPSC/NTSmedium
Sequence impedances Z1, Z2, Z0 are used to
💡 Explanation:Fortescue transformation decouples unbalanced networks.
- Q54Past Paper · PPSC/FPSC/NTSeasy
Fault MVA at a bus equals
💡 Explanation:Fault level indicates short-circuit severity for breaker rating.
- Q55Past Paper · PPSC/FPSC/NTSmedium
Subtransient reactance Xd″ of synchronous machine governs
💡 Explanation:Subtransient period has highest AC fault current from machines.
- Q56hard
Transient reactance Xd′ is relevant for
💡 Explanation:Current transitions from subtransient to transient level.
- Q57Past Paper · PPSC/FPSC/NTSmedium
DC offset component in fault current arises from
💡 Explanation:Offset decays with armature L/R time constant.
- Q58Past Paper · PPSC/FPSC/NTShard
Breaker making capacity must withstand
💡 Explanation:First-cycle peak can be substantially above symmetrical peak.
- Q59hard
Percentage DC component for breaker rating considers
💡 Explanation:High X/R yields slower offset decay and higher peak.
- Q60Past Paper · PPSC/FPSC/NTSmedium
Thevenin equivalent at fault bus for fault calculation uses
💡 Explanation:Vth and Zth simplify fault current computation.
- Q61Past Paper · PPSC/FPSC/NTSeasy
Solid fault means fault impedance is
💡 Explanation:Bolted fault assumes no additional impedance at fault point.
- Q62Past Paper · PPSC/FPSC/NTSmedium
Fault through impedance (e.g., arc) reduces
💡 Explanation:Arc resistance limits current during fault.
- Q63medium
Open conductor fault can cause
💡 Explanation:One or two open phases create severe unbalance.
- Q64Past Paper · PPSC/FPSC/NTSmedium
Distance relay measures
💡 Explanation:Z = V/I seen by relay estimates fault location.
- Q65Past Paper · PPSC/FPSC/NTSmedium
Bus impedance matrix (Z-bus) diagonal element Zii gives
💡 Explanation:Zii relates voltage at i to current injected at i.
- Q66Past Paper · PPSC/FPSC/NTSeasy
Post-fault voltage sag severity depends on
💡 Explanation:Stiff networks show smaller voltage depression during faults.
- Q67hard
Line charging and high R/X ratio can affect GS convergence by
💡 Explanation:Stiff networks favour Newton or fast decoupled methods.
- Q68medium
Removing a line from service updates Y-bus by
💡 Explanation:Topology changes alter incident admittances at affected nodes.
- Q69medium
Sparsity techniques in NR exploit
💡 Explanation:Sparse LU factorization reduces memory and CPU.