Power System Analysis and Load Flow MCQs 2026

69 questions with detailed answers · 44 from past papers · 7 quiz batches available

📚 Electrical Engineering📄 44 Past-Paper Qs✓ Free · No Login Needed
🎯 Mock Test

Read each question, think about the answer, then click Show Answer to reveal the correct option and explanation. Load 10 at a time so it stays manageable — perfect for one-topic study sessions on the bus or during a break.

Page 1 of 1Questions 1–10 of 69
  1. Q1medium

    Gauss-Seidel update for PQ bus uses

    1. Apower injection equations solved for new voltage estimate
    2. Bonly real power ignoring reactive
    3. Conly transformer tap without power
    4. Donly fault current
    💡 Explanation:

    Bus equations relate specified P,Q to surrounding voltages.

  2. Q2Past Paper · PPSC/FPSC/NTSeasy

    Admittance matrix Y-bus of a power network relates

    1. Aonly real power to angle only without voltage
    2. Bnodal current injections to nodal voltages via I = YV
    3. Conly transformer losses to frequency
    4. Donly cable tan delta to humidity
    💡 Explanation:

    Y-bus is the fundamental linear network model for load-flow and fault studies.

  3. Q3Past Paper · PPSC/FPSC/NTSmedium

    Diagonal element Yii of Y-bus equals

    1. Asum of all admittances connected to node i including shunt terms
    2. Bonly off-diagonal mutual terms
    3. Czero always
    4. Dreciprocal of line length only
    💡 Explanation:

    Self-admittance includes all branches incident on node i.

  4. Q4Past Paper · PPSC/FPSC/NTSmedium

    Off-diagonal element Yij of Y-bus for i ≠ j with direct branch between nodes is

    1. Apositive sum of all system admittances
    2. Balways zero in any network
    3. Cequal to transformer MVA only
    4. Dnegative of branch admittance between i and j
    💡 Explanation:

    Mutual terms are −yij for single series branch between nodes.

  5. Q5Past Paper · PPSC/FPSC/NTSeasy

    Y-bus of a large transmission network is typically

    1. Afully dense with all entries nonzero
    2. Bdiagonal only always
    3. Csparse because each node connects to few neighbours
    4. Didentity matrix
    💡 Explanation:

    Sparse structure enables efficient solution algorithms.

  6. Q6Past Paper · PPSC/FPSC/NTShard

    Including transformer off-nominal tap in Y-bus requires

    1. Aignoring tap completely always
    2. Bmodifying effective admittance and sometimes phase shift
    3. Cusing only resistance of conductor
    4. Dreplacing Y with Z always
    💡 Explanation:

    Tap ratio a affects both magnitude and angle of transformer model.

  7. Q7Past Paper · PPSC/FPSC/NTSmedium

    Line charging susceptance in π-model contributes to Y-bus as

    1. Ashunt admittance terms at line terminals
    2. Bonly series impedance without shunt
    3. Conly DC resistance
    4. Donly motor slip
    💡 Explanation:

    Half-line charging is placed at each end in nominal π representation.

  8. Q8Past Paper · PPSC/FPSC/NTSeasy

    Grounded shunt capacitor bank at a bus adds to Y-bus

    1. Apositive susceptance on the diagonal of that bus
    2. Bonly off-diagonal mutual terms
    3. Cnegative resistance on all buses
    4. Dzero change
    💡 Explanation:

    Capacitor increases jB at the connected node.

  9. Q9hard

    Mutual coupling between transmission lines on same tower appears in Y-bus as

    1. Aonly diagonal elements
    2. Bno effect in any case
    3. Coff-diagonal terms between corresponding nodes
    4. Donly in DC analysis
    💡 Explanation:

    Line coupling links electrically distinct node pairs.

  10. Q10Past Paper · PPSC/FPSC/NTSmedium

    Assembly of Y-bus from branch data is called

    1. Aonly Gauss-Seidel iteration
    2. Bonly per unit conversion of load only
    3. Conly symmetrical component reduction
    4. Dbuilding by successive addition of branch stamp contributions
    💡 Explanation:

    Each branch stamps its 2×2 (or larger) contribution into Y.

  11. Q11Past Paper · PPSC/FPSC/NTSeasy

    Per unit system simplifies Y-bus construction because

    1. Aall impedances become zero
    2. Bbranches on common bases add directly
    3. Cvoltage angles are eliminated
    4. Dloads disappear
    💡 Explanation:

    Consistent MVA and kV bases normalize network elements.

  12. Q12Past Paper · PPSC/FPSC/NTSmedium

    Singular Y-bus (no reference) occurs if

    1. Aall lines are lossless
    2. Ball loads are unity PF
    3. Cfrequency is exactly 50 Hz
    4. Dno ground/reference node is specified
    💡 Explanation:

    A reference node fixes one voltage magnitude and angle.

  13. Q13Past Paper · PPSC/FPSC/NTSmedium

    Z-bus is related to Y-bus by

    1. Asimple transposition only
    2. Bmatrix inversion Z = Y⁻¹ for nonsingular Y
    3. Cadding identity only
    4. Dsquaring each element
    💡 Explanation:

    Driving-point and transfer impedances come from Z-bus.

  14. Q14Past Paper · PPSC/FPSC/NTSmedium

    Modified Y-bus for fault studies may insert

    1. Afault admittance at faulted node
    2. Bonly transformer magnetizing branch removal
    3. Conly solar irradiance data
    4. Donly train mass
    💡 Explanation:

    Fault connection adds large admittance or alters network at fault point.

  15. Q15hard

    Three-phase Y-bus can be built from

    1. Aonly single-phase without coupling ever
    2. Bonly DC battery model
    3. Cphase network or from sequence networks with coupling
    4. Donly corona loss formula
    💡 Explanation:

    Unbalanced systems may require coupled 3n×3n Y or sequence methods.

  16. Q16Past Paper · PPSC/FPSC/NTSeasy

    Equivalent π parameters of a line branch for Y-bus come from

    1. Aseries impedance and total shunt admittance of line model
    2. Bonly tower height
    3. Conly insulator creepage
    4. Donly VFD carrier frequency
    💡 Explanation:

    π model yields series y and shunt jB/2 at each end.

  17. Q17Past Paper · PPSC/FPSC/NTSmedium

    Y-bus symmetry for passive network without phase shifters means

    1. AY is always diagonal
    2. BY is always real
    3. CY has no diagonal terms
    4. DYij = Yji for corresponding mutual entries
    💡 Explanation:

    Reciprocal network admittance matrix is symmetric.

  18. Q18hard

    Phase-shifting transformer introduces in Y-bus

    1. Aonly real diagonal terms
    2. Bcomplex mutual admittances with angle shift between buses
    3. Cno connection between buses
    4. Donly DC link
    💡 Explanation:

    PSD flow controllers modify power flow via phase angle injection.

  19. Q19Past Paper · PPSC/FPSC/NTSeasy

    Load-flow study computes

    1. Aonly transformer no-load loss
    2. Bonly motor starting current peak
    3. Cvoltage magnitudes and angles at buses for given generation and load
    4. Donly solar MPP only
    💡 Explanation:

    Steady-state power flow balances P and Q at each bus.

  20. Q20medium

    Weakly meshed distribution feeders may converge with GS when

    1. Anever under any condition
    2. Bonly with no loads
    3. Conly without slack
    4. Dsystem is not too stiff and initial guess is reasonable
    💡 Explanation:

    GS works for smaller or well-conditioned networks.

  21. Q21Past Paper · PPSC/FPSC/NTSeasy

    PV bus in load flow specifies

    1. Aactive power P and voltage magnitude V
    2. BP and Q both fixed
    3. CV and angle both fixed
    4. DQ and angle only
    💡 Explanation:

    PV (generator) bus controls P and V; Q varies to maintain V.

  22. Q22Past Paper · PPSC/FPSC/NTSeasy

    Slack (swing) bus in load flow specifies

    1. Aboth P and Q fixed always
    2. Bonly reactive load
    3. Czero voltage reference
    4. Dvoltage magnitude and angle to balance system power
    💡 Explanation:

    Slack absorbs mismatch in total P and Q generation vs load.

  23. Q23Past Paper · PPSC/FPSC/NTSeasy

    PQ bus in load flow specifies

    1. Avoltage magnitude and angle
    2. Bactive and reactive power demand P and Q
    3. Conly current magnitude
    4. Donly frequency deviation
    💡 Explanation:

    Load buses have specified P and Q; V is unknown.

  24. Q24Past Paper · PPSC/FPSC/NTSmedium

    Gauss-Seidel method solves load flow by

    1. Aonly Newton Jacobian inversion each step without iteration structure
    2. Bsuccessive substitution using updated values immediately
    3. Conly DC mesh analysis
    4. Donly symmetrical components only without voltages
    💡 Explanation:

    GS uses most recent voltages when updating each bus sequentially.

  25. Q25medium

    Acceleration factor in Gauss-Seidel can

    1. Aguarantee divergence always
    2. Beliminate need for slack bus
    3. Cspeed convergence of voltage iterations
    4. Dconvert AC to DC
    💡 Explanation:

    Over-relaxation (α > 1) may improve convergence rate.

  26. Q26Past Paper · PPSC/FPSC/NTSmedium

    Convergence of Gauss-Seidel is generally

    1. Aslower than Newton-Raphson for large systems
    2. Balways faster than NR always
    3. Cindependent of R/X ratio
    4. Dguaranteed in one iteration
    💡 Explanation:

    NR quadratic convergence beats GS linear rate for tight tolerance.

  27. Q27Past Paper · PPSC/FPSC/NTSeasy

    Initial voltage guess for GS load flow often sets

    1. Aall voltages zero
    2. Brandom negative magnitudes
    3. Conly DC values
    4. Dflat start: 1.0 pu angle 0° except slack
    💡 Explanation:

    Flat start is common unless better estimate available.

  28. Q28Past Paper · PPSC/FPSC/NTShard

    Reactive power limit violation at PV bus during GS iteration requires

    1. Aignoring limits always
    2. Bremoving slack bus
    3. Cswitching bus type from PV to PQ temporarily
    4. Dsetting frequency to zero
    💡 Explanation:

    When Q hits limit, voltage can no longer be held; bus becomes PQ.

  29. Q29easy

    Number of iterations in GS depends on

    1. Aonly utility tariff
    2. Bonly motor poles
    3. Conly solar STC
    4. Dtolerance, acceleration and network parameters
    💡 Explanation:

    Tighter ε and difficult cases need more passes.

  30. Q30Past Paper · PPSC/FPSC/NTSmedium

    After GS converges, line flows are computed from

    1. Abus voltages and branch admittances
    2. Bonly nameplate MVA
    3. Conly rotor resistance
    4. Donly braking resistor size
    💡 Explanation:

    Sij = Vi(Vi−Vj)Yij* etc. from solved voltages.

  31. Q31easy

    Gauss-Seidel is attractive for teaching because

    1. Ait never requires iteration
    2. Bit solves nonlinear equations in closed form
    3. Calgorithm is simple and needs little memory
    4. Dit eliminates Y-bus
    💡 Explanation:

    Educational simplicity; less used in large commercial tools than NR.

  32. Q32Past Paper · PPSC/FPSC/NTSmedium

    Mismatch at a bus in load flow is

    1. Aonly voltage magnitude without angle
    2. Bdifference between specified and calculated power injection
    3. Conly frequency error
    4. Donly transformer iron loss
    💡 Explanation:

    ΔP and ΔQ drive iterative correction toward convergence.

  33. Q33Past Paper · PPSC/FPSC/NTSeasy

    Stopping criterion for GS typically checks

    1. Aonly one bus voltage exactly
    2. Bonly number of lines
    3. Conly solar fill factor
    4. Dmaximum power mismatch below tolerance
    💡 Explanation:

    max|ΔP|,|ΔQ| < ε across buses ends iteration.

  34. Q34hard

    Distributed slack shares

    1. Aall loss to one bus only always
    2. Bslack bus responsibility among multiple generators by participation factors
    3. Cno slack needed ever
    4. Donly reactive load at slack
    💡 Explanation:

    Multiple slack generators share imbalance per defined weights.

  35. Q35Past Paper · PPSC/FPSC/NTSmedium

    Newton-Raphson load flow linearizes

    1. Aonly DC resistance network without angles
    2. Bonly single-phase DC battery
    3. Cpower mismatch equations using Taylor expansion and Jacobian
    4. Donly corona power loss
    💡 Explanation:

    NR solves ΔF = −J·Δx iteratively.

  36. Q36Past Paper · PPSC/FPSC/NTShard

    Jacobian matrix in NR contains partial derivatives of

    1. Apower mismatches with respect to voltage angles and magnitudes
    2. Bonly line resistance
    3. Conly train mass
    4. Donly biomass moisture
    💡 Explanation:

    J includes ∂P/∂θ, ∂P/∂V, ∂Q/∂θ, ∂Q/∂V blocks.

  37. Q37hard

    Quadratic convergence of Newton-Raphson near solution means

    1. Aerror is constant each step
    2. Berror squares each iteration when close to root
    3. Cdivergence always
    4. Dlinear halving only
    💡 Explanation:

    Good initial guess yields very fast NR convergence.

  38. Q38Past Paper · PPSC/FPSC/NTSmedium

    Fast decoupled load flow approximates Jacobian by

    1. Aignoring all reactive power
    2. Busing only DC analysis forever
    3. Cdecoupling P-θ and Q-V assuming high X/R lines
    4. Deliminating slack bus
    💡 Explanation:

    B′ and B″ matrices replace full Jacobian for speed.

  39. Q39Past Paper · PPSC/FPSC/NTSmedium

    PV bus treatment in NR includes

    1. Aequations for P and V with Q within limits
    2. Bonly Q and θ specified
    3. Cno reactive power variable
    4. Dfixed Q always
    💡 Explanation:

    PV buses add P-specified equation and V magnitude constraint.

  40. Q40hard

    Ill-conditioned cases for NR include

    1. Aunloaded open circuit only
    2. Bheavy loading near voltage collapse and low impedance ties
    3. Csingle slack only
    4. Dlossless lines only
    💡 Explanation:

    Near singularity of J slows or stalls convergence.

  41. Q41hard

    Rectangular coordinates (e,f) alternative in NR uses

    1. Aonly magnitude without angle ever
    2. Bonly frequency deviation
    3. Creal and imaginary parts of voltage instead of polar V,θ
    4. Donly per unit resistance alone
    💡 Explanation:

    Rectangular form avoids trig in some formulations.

  42. Q42hard

    Optimal multiplier in NR can

    1. Aincrease mismatch intentionally
    2. Bremove Jacobian
    3. Cfix all angles at zero
    4. Ddamp step size to improve global convergence
    💡 Explanation:

    Line search/optimal multiplier helps difficult cases.

  43. Q43hard

    After NR solution, LMP or marginal loss calculations may use

    1. Asolved voltages and sensitivity factors
    2. Bonly guesswork
    3. Conly motor nameplate
    4. Donly wind cut-out
    💡 Explanation:

    Post-convergence analytics use power flow Jacobian inverse sensitivities.

  44. Q44hard

    Continued power flow uses NR with parameterization to trace

    1. Aonly transformer OC test
    2. Bonly cable tan delta
    3. Conly VFD ramp
    4. DP-V nose curve toward voltage collapse point
    💡 Explanation:

    CPF finds maximum loadability margin.

  45. Q45Past Paper · PPSC/FPSC/NTSeasy

    NR is preferred in commercial EMS for

    1. Asmallest possible 2-bus homework only always
    2. Breliable fast convergence on large transmission networks
    3. Csystems without any nonlinearities
    4. DDC circuits only
    💡 Explanation:

    Industry standard for bulk power flow.

  46. Q46hard

    Symmetric Jacobian structure is not generally symmetric because

    1. AY-bus is complex
    2. Ball loads are zero
    3. Cmixing of P and Q equations with θ and V variables breaks symmetry
    4. Dfrequency is variable
    💡 Explanation:

    Full NR Jacobian is nonsymmetric though Y may be symmetric.

  47. Q47Past Paper · PPSC/FPSC/NTSmedium

    Updating voltage in polar NR computes

    1. Acorrections Δθ and ΔV/ V from solved linear system
    2. Bonly Δf frequency
    3. Conly transformer tap without voltage
    4. Donly DC link current
    💡 Explanation:

    Corrections added to current θ and V each iteration.

  48. Q48medium

    Flat start for NR on stiff EHV system may require

    1. Ano iteration at all
    2. Bbetter initial voltages or damping to avoid early divergence
    3. Cremoving all loads
    4. Dsetting all P to zero
    💡 Explanation:

    Difficult cases need engineering initial guesses or homotopy.

  49. Q49hard

    Transformer regulating tap change during NR may use

    1. Acontinuous tap without limits always
    2. Bno tap model
    3. Cdiscrete tap steps outer loop around continuous NR
    4. Donly mechanical brake model
    💡 Explanation:

    Tap is discrete; outer control adjusts tap after flow solution.

  50. Q50medium

    Loss allocation after NR can use

    1. Aonly guess without voltages
    2. Bonly solar azimuth angle
    3. Conly corona RI
    4. Dincremental loss factors or proportional sharing methods
    💡 Explanation:

    Loss formulas distribute line losses to generators/loads.

  51. Q51Past Paper · PPSC/FPSC/NTSeasy

    Symmetrical three-phase fault has

    1. Aequal fault currents in all phases with zero sequence unaffected if ungrounded
    2. Bonly single line open
    3. Conly DC offset in one phase without AC
    4. Donly negative sequence only
    💡 Explanation:

    Balanced fault simplifies to positive sequence network only.

  52. Q52Past Paper · PPSC/FPSC/NTSmedium

    Line-to-line fault (LL) contains

    1. Aall three sequences always including zero
    2. Bonly zero sequence
    3. Cpositive and negative sequence components without zero sequence if ungrounded
    4. Donly DC component
    💡 Explanation:

    LL is unbalanced but lacks zero sequence if system ungrounded.

  53. Q53Past Paper · PPSC/FPSC/NTSmedium

    Sequence impedances Z1, Z2, Z0 are used to

    1. Aanalyze unbalanced faults via symmetrical components
    2. Bonly calculate solar fill factor
    3. Conly VFD carrier
    4. Donly train adhesion
    💡 Explanation:

    Fortescue transformation decouples unbalanced networks.

  54. Q54Past Paper · PPSC/FPSC/NTSeasy

    Fault MVA at a bus equals

    1. Aonly real load MW
    2. B√3 × kV_line × kA_fault (three-phase basis) or V²/|Zf| in consistent units
    3. Conly transformer iron loss
    4. Donly cable length
    💡 Explanation:

    Fault level indicates short-circuit severity for breaker rating.

  55. Q55Past Paper · PPSC/FPSC/NTSmedium

    Subtransient reactance Xd″ of synchronous machine governs

    1. Aonly steady-state thermal limit
    2. Bonly governor droop only
    3. Conly excitation ceiling at steady state
    4. Dinitial symmetrical short-circuit current contribution
    💡 Explanation:

    Subtransient period has highest AC fault current from machines.

  56. Q56hard

    Transient reactance Xd′ is relevant for

    1. Aonly DC time constant of armature
    2. Bonly long-term steady state only
    3. Cfault current decay in first few cycles
    4. Donly solar Voc
    💡 Explanation:

    Current transitions from subtransient to transient level.

  57. Q57Past Paper · PPSC/FPSC/NTSmedium

    DC offset component in fault current arises from

    1. Ainductance opposing sudden current change making current asymmetric
    2. Bonly solar irradiance change
    3. Conly biomass moisture
    4. Donly PWM switching
    💡 Explanation:

    Offset decays with armature L/R time constant.

  58. Q58Past Paper · PPSC/FPSC/NTShard

    Breaker making capacity must withstand

    1. Aonly RMS symmetrical value always
    2. Bpeak asymmetrical fault current including DC offset
    3. Conly load current
    4. Donly charging current
    💡 Explanation:

    First-cycle peak can be substantially above symmetrical peak.

  59. Q59hard

    Percentage DC component for breaker rating considers

    1. AX/R ratio at fault point affecting asymmetry
    2. Bonly cable colour
    3. Conly tower paint
    4. Donly motor poles only
    💡 Explanation:

    High X/R yields slower offset decay and higher peak.

  60. Q60Past Paper · PPSC/FPSC/NTSmedium

    Thevenin equivalent at fault bus for fault calculation uses

    1. Aonly load power factor
    2. Bonly solar MPP
    3. Cprefault voltage and equivalent impedance looking into network
    4. Donly train schedule
    💡 Explanation:

    Vth and Zth simplify fault current computation.

  61. Q61Past Paper · PPSC/FPSC/NTSeasy

    Solid fault means fault impedance is

    1. Ainfinite
    2. Bequal to surge impedance only
    3. Cequal to load resistance
    4. Dzero
    💡 Explanation:

    Bolted fault assumes no additional impedance at fault point.

  62. Q62Past Paper · PPSC/FPSC/NTSmedium

    Fault through impedance (e.g., arc) reduces

    1. Avoltage at remote buses to zero always
    2. Bfault current magnitude compared with solid fault
    3. Cneed for any protection
    4. Dsequence impedance to zero
    💡 Explanation:

    Arc resistance limits current during fault.

  63. Q63medium

    Open conductor fault can cause

    1. Aperfect balance always
    2. Bonly symmetrical fault
    3. Cno effect on loads
    4. Dunbalance and abnormal voltages on unaffected phases
    💡 Explanation:

    One or two open phases create severe unbalance.

  64. Q64Past Paper · PPSC/FPSC/NTSmedium

    Distance relay measures

    1. Aonly transformer temperature
    2. Bonly solar azimuth
    3. Cimpedance to fault to trip appropriate line section
    4. Donly biogas pressure
    💡 Explanation:

    Z = V/I seen by relay estimates fault location.

  65. Q65Past Paper · PPSC/FPSC/NTSmedium

    Bus impedance matrix (Z-bus) diagonal element Zii gives

    1. Aonly off-diagonal mutual terms
    2. Bdriving-point impedance at bus i for fault calculations
    3. Conly shunt capacitance
    4. Donly motor slip
    💡 Explanation:

    Zii relates voltage at i to current injected at i.

  66. Q66Past Paper · PPSC/FPSC/NTSeasy

    Post-fault voltage sag severity depends on

    1. Afault level, impedance to fault and prefault voltage
    2. Bonly solar panel tilt
    3. Conly VFD ramp time only
    4. Donly train pantograph material only
    💡 Explanation:

    Stiff networks show smaller voltage depression during faults.

  67. Q67hard

    Line charging and high R/X ratio can affect GS convergence by

    1. Aimproving conditioning always
    2. Bmaking equations more ill-conditioned
    3. Celiminating reactive power
    4. Dfixing all angles to zero
    💡 Explanation:

    Stiff networks favour Newton or fast decoupled methods.

  68. Q68medium

    Removing a line from service updates Y-bus by

    1. Ainverting Z-bus only without change
    2. Bmultiplying all elements by zero
    3. Csubtracting that branch stamp from the matrix
    4. Dadding random entries
    💡 Explanation:

    Topology changes alter incident admittances at affected nodes.

  69. Q69medium

    Sparsity techniques in NR exploit

    1. Adense matrix inversion always
    2. Bno branch data
    3. Conly 2-bus systems
    4. Dfew nonzero Jacobian entries in large networks
    💡 Explanation:

    Sparse LU factorization reduces memory and CPU.