Illumination and Lighting Engineering MCQs 2026

40 questions with detailed answers · 25 from past papers · 4 quiz batches available

📚 Electrical Engineering📄 25 Past-Paper Qs✓ Free · No Login Needed
🎯 Mock Test

Read each question, think about the answer, then click Show Answer to reveal the correct option and explanation. Load 10 at a time so it stays manageable — perfect for one-topic study sessions on the bus or during a break.

Page 1 of 1Questions 1–10 of 40
  1. Q1Past Paper · PPSC/FPSC/NTSeasy

    Luminous flux is measured in

    1. Alumen (lm)
    2. Blux only without area
    3. Ccandela-second only
    4. Dwatt
    💡 Explanation:

    Lumen quantifies total visible light output from a source.

  2. Q2easy

    Light pollution from poor street lighting design is reduced by

    1. Afull cut-off optics and curfew dimming where permitted
    2. Baiming luminaires at sky
    3. Cusing only bare lamps on low poles
    4. Dmaximizing uplight for ambiance
    💡 Explanation:

    Sky glow affects astronomy and ecosystems; control uplight.

  3. Q3hard

    Series street lighting (historical) used

    1. Aparallel household wiring only
    2. Bonly DC traction feeder
    3. Cconstant current series circuit with isolation transformers
    4. Donly open-delta transformer without lamps
    💡 Explanation:

    Series loop carried constant current through lamp isolators.

  4. Q4Past Paper · PPSC/FPSC/NTShard

    International practice for road lighting classes considers

    1. Aonly conductor strand count
    2. Bonly fuse element alloy only
    3. Ctraffic volume, road type and pedestrian conflict areas
    4. Donly synchronous condenser rating
    💡 Explanation:

    Standards define illuminance, uniformity and glare limits.

  5. Q5medium

    Pole setback and overhang influence

    1. Aonly neutral current in 4-wire system
    2. Bonly rotor resistance of slip-ring motor
    3. Conly Buchholz relay gas volume
    4. Dlight distribution on carriageway and footpath
    💡 Explanation:

    Bracket length positions luminaire over target pavement areas.

  6. Q6Past Paper · PPSC/FPSC/NTSeasy

    LED street lighting retrofit often improves

    1. Aonly THD without any lumen gain
    2. Bonly pole weight without optics
    3. Cefficacy, life and controllability (dimming/scheduling)
    4. Donly earth resistance of rod
    💡 Explanation:

    Smart controls save energy while maintaining safety lux.

  7. Q7Past Paper · PPSC/FPSC/NTSmedium

    Spacing between street lights is increased when

    1. Aonly when lamps are removed
    2. Bmounting height and luminaire candela distribution allow
    3. Conly when voltage is reduced 50%
    4. Donly when power factor is zero
    💡 Explanation:

    Optics and height set economic pole spacing.

  8. Q8medium

    Semi-cut-off and non-cut-off street lanterns differ in

    1. Aamount of light allowed above horizontal (upward light)
    2. Bonly lamp wattage without optics
    3. Conly pole material wood vs steel
    4. Donly supply neutral earthing
    💡 Explanation:

    IES/CIE classifications define upward light limits.

  9. Q9Past Paper · PPSC/FPSC/NTSmedium

    Average lux on road surface in street lighting design uses

    1. Aonly Ohm law of conductor
    2. Bonly Ferranti effect formula
    3. Conly welding heat input equation
    4. Dlumen method with utilization factor and maintenance factor
    💡 Explanation:

    Φ = E × A / (UF × MF) determines luminaire lumens needed.

  10. Q10Past Paper · PPSC/FPSC/NTSmedium

    Mounting height of street lights affects

    1. Aonly transformer tap position
    2. Bonly cable insulation thickness only
    3. Cspacing, uniformity and glare on the roadway
    4. Donly motor synchronous speed
    💡 Explanation:

    Higher mounting allows wider spacing with acceptable uniformity.

  11. Q11Past Paper · PPSC/FPSC/NTSeasy

    Cut-off luminaire in street lighting directs light

    1. Aonly into the sky for astronomy
    2. Bdownward to the road with limited upward spill
    3. Conly into adjacent property without control
    4. Donly horizontally at eye level
    💡 Explanation:

    Cut-off reduces glare and light pollution.

  12. Q12easy

    Lamp life rating (e.g., 1000 h incandescent, 50000 h LED) indicates

    1. Aguaranteed illuminance lux level
    2. Bmaximum supply voltage
    3. Cearth loop impedance
    4. Dstatistical median or rated hours to replacement criteria
    💡 Explanation:

    Life depends on voltage, switching cycles and environment.

  13. Q13Past Paper · PPSC/FPSC/NTSmedium

    Metal halide lamps are preferred for

    1. Aonly indicator pilot lamps
    2. Bgood color rendering and high efficacy in sports/factory lighting
    3. Conly series street lighting without gear
    4. Donly battery trickle charge
    💡 Explanation:

    Metal halide offers white light with high lm/W.

  14. Q14medium

    Starting voltage for fluorescent tube is highest at

    1. Ahighest temperature always
    2. Bzero humidity only condition
    3. Clowest ambient temperature
    4. Dfull lamp lumen output
    💡 Explanation:

    Cold cathodes need higher strike voltage.

  15. Q15Past Paper · PPSC/FPSC/NTSmedium

    Power factor of magnetic-ballast fluorescent luminaire is often improved by

    1. Aremoving capacitor entirely always
    2. Bhigh power factor or electronic ballast
    3. Cusing only resistance ballast for unity PF
    4. Dincreasing THD without correction
    💡 Explanation:

    Electronic ballasts improve PF and reduce flicker.

  16. Q16Past Paper · PPSC/FPSC/NTSeasy

    LED lamp efficacy compared to incandescent is generally

    1. Aalways lower than 10 lm/W
    2. Bequal to candle only
    3. Cindependent of junction temperature
    4. Dmuch higher (often 80–150+ lm/W)
    💡 Explanation:

    Semiconductor electroluminescence is far more efficient.

  17. Q17medium

    Tungsten halogen cycle in halogen lamps

    1. Aredeposits evaporated tungsten back on the filament
    2. Beliminates all heat from filament
    3. Creplaces need for glass envelope
    4. Dconverts AC to DC
    💡 Explanation:

    Halogen gas helps maintain filament and envelope clarity.

  18. Q18Past Paper · PPSC/FPSC/NTSmedium

    High intensity discharge (HID) lamps include

    1. Amercury vapor, metal halide and high-pressure sodium
    2. Bonly tungsten halogen without discharge
    3. Conly neon sign electrodes without arc
    4. Donly LED chip arrays
    💡 Explanation:

    HID types use arc discharge through gases/metals.

  19. Q19Past Paper · PPSC/FPSC/NTSeasy

    Compact fluorescent lamp (CFL) advantage over incandescent is

    1. Alower efficacy than incandescent
    2. Bno need for any phosphor
    3. Chigher luminous efficacy and longer life
    4. Doperation without any ballast ever
    💡 Explanation:

    CFL typically 50–70 lm/W versus ~15 lm/W incandescent.

  20. Q20Past Paper · PPSC/FPSC/NTSeasy

    Fluorescent lamp requires ballast to

    1. Aincrease filament resistance to infinity
    2. Bconvert AC to DC at load only
    3. Cmeasure earth fault current
    4. Dlimit current and provide starting voltage
    💡 Explanation:

    Gas discharge has negative resistance characteristic.

  21. Q21Past Paper · PPSC/FPSC/NTSeasy

    Incandescent lamp light is produced by

    1. Agas discharge in mercury vapor only
    2. Bheating a tungsten filament to incandescence
    3. CLED junction electroluminescence
    4. Dchemical combustion of fuel
    💡 Explanation:

    Thermal radiation from hot filament; low efficacy.

  22. Q22hard

    Spacing to height ratio (SHR) in interior lighting relates to

    1. Ashort-circuit level of substation
    2. Buniformity of illuminance for a given luminaire distribution
    3. Ctransformer impedance only
    4. Dwelding electrode diameter only
    💡 Explanation:

    SHR limits spacing for acceptable uniformity on the working plane.

  23. Q23hard

    Color rendering index (CRI) degradation in aging lamps

    1. Amay be considered alongside lumen depreciation in critical areas
    2. Bis unrelated to lighting maintenance
    3. Creplaces illuminance calculation entirely
    4. Deliminates glare completely
    💡 Explanation:

    Retail and inspection areas may relamp when CRI falls.

  24. Q24Past Paper · PPSC/FPSC/NTSeasy

    Emergency lighting levels are maintained considering

    1. Aappropriate MF and minimum lux codes for escape routes
    2. Bonly decorative color temperature
    3. Conly highest HF ballast THD
    4. Donly motor pull-out torque
    💡 Explanation:

    Safety codes specify minimum maintained emergency illuminance.

  25. Q25medium

    Design illuminance with MF less than unity means installed initial lux is

    1. Alower than maintained always
    2. Bequal to zero always
    3. Chigher than the target maintained illuminance
    4. Dindependent of lamp choice
    💡 Explanation:

    Initial overdesign compensates for future depreciation.

  26. Q26Past Paper · PPSC/FPSC/NTSmedium

    For LED luminaires, lumen maintenance is often quoted as

    1. Aonly peak candela at 1 ms
    2. BL70 or L80 life (hours to 70% or 80% initial lumens)
    3. Conly THD of driver
    4. Donly earth resistance
    💡 Explanation:

    Long LED life uses slow lumen depreciation curves.

  27. Q27easy

    Cleaning luminaires on schedule improves

    1. Aonly power factor of supply
    2. Bonly cable insulation resistance
    3. Conly short-circuit MVA
    4. Deffective lumens reaching the work plane
    💡 Explanation:

    Removing dirt raises realized illuminance without extra power.

  28. Q28medium

    Relamping before average lamp life in group relamping

    1. Aalways wastes all lamps instantly
    2. Beliminates need for MF
    3. Cmaintains more uniform illuminance than spot relamping alone
    4. Dreduces efficacy to zero
    💡 Explanation:

    Group relamping balances labor cost and light level uniformity.

  29. Q29Past Paper · PPSC/FPSC/NTSmedium

    Combined maintenance factor MF is typically

    1. Asum of LLD and DDF only
    2. Balways equal to 2
    3. Cproduct of LLD and DDF (and other factors if used)
    4. Dindependent of cleaning schedule
    💡 Explanation:

    MF = LLD × DDF ensures design illuminance at maintenance cycle end.

  30. Q30Past Paper · PPSC/FPSC/NTSmedium

    Dirt depreciation factor (DDF) in lighting allows for

    1. Aincreased lamp voltage only
    2. Bmotor starting current
    3. Ctransformer tap change
    4. Dreduced light output due to dust on luminaires and room surfaces
    💡 Explanation:

    Industrial dusty areas need lower DDF (more allowance).

  31. Q31Past Paper · PPSC/FPSC/NTSeasy

    Lamp lumen depreciation (LLD) factor represents

    1. Aratio of voltage to current
    2. Bpower factor of ballast only
    3. Cratio of lumens at end of life to initial lumens
    4. Dcable derating factor
    💡 Explanation:

    LLD accounts for aging of lamps before replacement.

  32. Q32easy

    Glare in lighting installations is reduced by

    1. Ausing only bare lamps at low height
    2. Bmaximizing direct glare toward eyes
    3. Celiminating all diffusers always
    4. Dproper shielding, mounting height and limiting luminance of sources
    💡 Explanation:

    Cut-off luminaires and positioning control discomfort glare.

  33. Q33medium

    Utilization factor (UF) in interior lighting depends on

    1. Aonly conductor resistivity
    2. Bonly breaker making capacity
    3. Conly grid frequency deviation
    4. Droom geometry, reflectances and luminaire photometrics
    💡 Explanation:

    UF fraction of lamp lumens reaching the work plane.

  34. Q34Past Paper · PPSC/FPSC/NTSmedium

    Maintenance factor (MF) in lighting design accounts for

    1. Aonly supply voltage rise
    2. Blamp lumen depreciation and dirt depreciation over maintenance period
    3. Conly transformer iron loss
    4. Donly motor slip
    💡 Explanation:

    MF < 1 ensures illuminance stays above minimum until relamping/cleaning.

  35. Q35Past Paper · PPSC/FPSC/NTSmedium

    Luminous flux required on a work plane depends on

    1. Arequired illuminance and area (Φ = E × A)
    2. Bonly lamp voltage
    3. Conly power factor of motor
    4. Donly cable length
    💡 Explanation:

    Total lumens ≈ desired lux times area divided by utilization factors.

  36. Q36Past Paper · PPSC/FPSC/NTSmedium

    A 100 W incandescent lamp producing 1700 lm has efficacy about

    1. A17 lm/W
    2. B100 lm/W
    3. C1.7 lm/W
    4. D170 lm/W
    💡 Explanation:

    Efficacy = 1700/100 = 17 lm/W; incandescent is inefficient.

  37. Q37Past Paper · PPSC/FPSC/NTSeasy

    Luminous efficacy of a light source is

    1. Awatts per lumen always below 1
    2. Blumens produced per watt of input power
    3. Ccandela per meter only
    4. Dpower factor of lamp only
    💡 Explanation:

    Higher lm/W indicates more efficient conversion to visible light.

  38. Q38Past Paper · PPSC/FPSC/NTSeasy

    Luminous intensity of a point source is measured in

    1. Acandela (cd)
    2. Blux
    3. Clumen per hour
    4. Dohm
    💡 Explanation:

    Candela is lumens per steradian in a given direction.

  39. Q39medium

    One lumen is defined in relation to

    1. Aonly IR radiation power
    2. Bradiant flux weighted by the luminous efficiency function V(λ)
    3. Conly magnetic flux in weber
    4. Donly cable charging VAR
    💡 Explanation:

    Photopic vision weighting converts radiant W to lumens.

  40. Q40Past Paper · PPSC/FPSC/NTSeasy

    Illuminance on a surface is measured in

    1. Acandela only
    2. Blumen
    3. Cwatt per steradian
    4. Dlux (lx)
    💡 Explanation:

    Lux = lumens per square meter incident on the surface.